Recently, Royole Technology has successfully developed the thinnest and mass-produced flexible display backplane in the world. The thickness is less than the diameter of the hairline and the thinnest is 0.03mm to 0.1mm. It is reported that Flexo Technologies developed a prototype of a flexible display more than a year ago. This time, it is expected that the flexible display will be transformed from a sample into a usable product. Smartphones, tablet PCs, portable TVs and other products can be carried Flexible display screen.
According to reports, flexible displays include features such as light weight, flexibility, high portability, and high degree of freedom in industrial design. The key difficulty in productization is to achieve a control backplane with stable performance and large-scale production.
The backboard technology successfully developed by Rouyu Technology solves the problem that most flexible display samples can only be used for short-term display, and is compatible with all major display systems, including OLED, electronic ink, and LCD. The flexible display realized by this technology has extremely strong flexibility and stability, and the crimp radius can reach the order of millimeters.
Chemical Industry Mass Flow Meter
Sealand is a professional supplier of Chemical Mass Flow Meter, Chemical Mass Flowmeter, Chemical Flowmeter, Chemical Flow Meter, Chemical Coriolis Meter, ATEX, IECEx & CE approved.
The meter can work with a pulse receiver(Count). The connection is as follows. The resistance value is up to the cable length & the max. input pulse frequency of receiver. Current 10mA is suitable for most receivers; however, you can reduce the resistance value when the cable is long. The max. current could be 50mA. Please use the fixed frequency output function to check if the cable length & resistance value is suitable.
Please check following items before operation, and operate according to relevant rules.
a) If the meter is damaged during shipment and installation;
b) If the voltage is same as marked on nameplate;
c) If the fuse is correct;
d) If the meter is grounded properly.
e) If the Meter SN on the nameplate of sensor and transmitter are the same.
If everything is fine, please open all valves, make the pipeline full of liquid and then power on
the meter for warm-up for 20min before operation. Finally, conduct zero calibration after first
start, and shall do it again if the meter is moved to another site.
Preparation for zero calibration:
a) Power on the meter for approximately 20min for warm-up;
b) Run the process fluid through the sensor until the sensor temperature reaches the normal
process operating temperature.
c) Close the shutoff valve downstream from the sensor.
d) Ensure that the sensor is filled with fluid and the process flow has completely stopped.
Chemical Mass Flow Meter, Chemical Mass Flowmeter, Chemical Flowmeter, Chemical Flow Meter, Chemical Coriolis Meter
Zhejiang Sealand Technology Co., Ltd. , https://www.sealandflowmeter.com